EG4 Monitor Center Web Portal & App (18kPV / 12kPV / 6000XP)Full Granular Control Over 3 Time-Windows per Mode

EG4 18kPV & 6000XP Working Modes Guide: Self-Consumption, AC Charge, Peak Shaving & Grid Sell-Back

The EG4 18kPV is the most configurable hybrid inverter in North America—which also means its 30+ settings in the EG4 Monitor Center can intimidate first-time owners. Here is the plain-English cheat sheet to configuring Self-Consumption, Charge First, AC Charge, Forced Discharge, and Peak Shaving.

Recommended Reserve / SoC Window
20% On-Grid EOD (End of Discharge) / 10% Off-Grid EOD
Best Utility & Grid Application
All US Grid-Tied, Zero-Export & Off-Grid Configurations

📲 Step-by-Step App & Firmware Configuration Walkthrough

01

Default Mode (Self-Consumption): When none of the special time-window overrides (AC Charge, Charge First, Forced Discharge) are active, the 18kPV runs in Self-Consumption automatically: Solar powers house loads first -> Surplus solar charges the LFP battery -> Once battery is 100%, surplus exports to the grid (if Grid Sell Back is enabled). When solar drops in the evening, the battery powers the house down to your "On-Grid Cut-Off SoC %" (set to 20%).

02

Setting "On-Grid Cut-Off SoC" vs "Off-Grid Cut-Off SoC": Under Discharge Control, set On-Grid Cut-Off to 20%–25% and Off-Grid Cut-Off to 10%. That way, normal nightly usage stops at 20%, automatically saving the remaining 10%–20% exclusively for power outages!

03

Using "Forced Discharge" for NEM 3.0 / Peak Export Arbitrage: Enable Forced Discharge and set Window 1 from 17:00 to 20:00 (5 PM–8 PM) at 8,000W down to 25% SoC to dump battery power during utility peak rates.

04

Using "Charge First (PV)": Enable Charge First between 08:00 and 15:00 if you want 100% of solar power to fill the battery before feeding non-backed-up main panel loads.

💡 Master Installer Pro-Tips & Optimization Shortcuts

  • ✓Always click "Read" at the top of the EG4 Monitor Maintenance page BEFORE changing any parameter so you see the inverter's current live values first!
  • ✓Order pre-configured EG4 18kPV + PowerPro WallMount bundles via /go/eg4.

Frequently Asked Questions: EG4 18kPV Working Modes Guide

Why is my EG4 18kPV not discharging the battery to power my house at night?

Check three settings in EG4 Monitor: (1) Make sure "AC Charge" or "Charge First" time windows are not accidentally set to 00:00–23:59 (which locks the battery in charge-only standby all night!), (2) Verify current Battery SoC is higher than your "On-Grid Cut-Off SoC %", and (3) Ensure "Power Backup / Seamless EPS" is enabled.